台风机盘管一般设一个送风口;送、回风口距离超过7m但小于10m时,可一台风机盘管设两个送风口;超过10m时宜设两排及以上风机盘管。一台风机盘管一般设一个回风口。送风管就是风机盘管与送风口的连接管。
The general set up a fan coil outlet; inlet and outlet distance of more than 7m but less than 10m, a fan coil with two diffusers; more than 10m should be set above the two row and fan coil. A typhoon machine coil is usually provided with an air outlet. The air supply pipe is the connecting pipe of the fan coil pipe and the air outlet.
回风管就是风机盘管与回风口的连接管(有的习题风机盘管带回风口,也就带了回风管)。风机盘管的送风口与回风口不在同一水平面时(如送风口为上侧送、回风口为上回),送风口与回风口距离可相对近一些。
The return tube is fan coil and air outlet connecting pipe (some exercise fan coil is brought back to the air, return air duct). Fan coil air outlet and the air return are not at the same level (such as when the outlet for side inlet and outlet for the last time), air inlet and the air return distance can be relatively close.
风机盘管的送风口与回风口在同一水平面时(如送风口为上侧送、回风口为上侧回;送风口为上送、回风口为上回等),送风口与回风口不宜太近,尽量远一些。送风口中心距墙不宜小于1m,因送风口一般为散流器,从风口向斜下方吹的气流遇到墙后向下,会使向下的气流过大。
Fan coil air outlet and the air inlet at the same level (such as the outlet for side inlet and outlet for the upper back; outlet for inlet and outlet for the last time, etc.) air inlet and the air return should not be too close, some as far as possible. The outlet center distance of the wall should not be less than 1m, because the air is generally diffuser airflow from the air blowing up the wall below the ramp down, the downward flow is too large.
为使室内维持一定的新鲜空气量,要根据人员多少、停留时间、污染程度等因素把室外空气经过加热、冷却、加湿、过滤等处理后单独送入房间。习题对新风管的连接有要求时,如:新风接风机盘管入口、新风接风机盘管出(送)风管等,按题目的要求布置;题目无要求时,新风单独接风口。新风送入房间后经过人的呼吸不再新鲜,要排出房间以使新风再进入。
In order to maintain a certain amount of fresh air in the room, according to the number of personnel, residence time, the degree of pollution and other factors of the outdoor air after heating, cooling, humidification, filtering and other processing into the room alone. Exercise is required for the fresh air pipe connection, such as: air blower, air blower coil pipe entrance out (send) air pipe, according to the requirements of the layout of the problem; the topic request, separately after fresh air outlet. Fresh air into the room after the breath is no longer fresh, to discharge the room so that fresh air into.
本文的精彩内容由济南空调维修提供,更多的内容请点击我们的官方网站:http://www.jnslshwx.com或者来电咨询。
The highlight of this article by the Ji'nan air conditioning maintenance, more content, please click on our official website: http://www.jnslshwx.com or call advisory.

上一篇:中央空调水蓄冷系统的设计
下一篇:空调制冷不制热的原因