收藏本站联系我们 您好,欢迎来到济南空调维修,济南空调安装,三联家电售后服务中心!

新闻中心
当前位置:首页-新闻中心 >

蒸发器除霜存在哪些问题?

来源:http://www.jnslshwx.com 日期:2019-07-11 发布人:admin
  虽然蒸发器非常容易使用,但在使用的过程中出现在蒸发器除霜电加热管烧坏了,水盘加热房间烧坏了,所以小编介绍蒸发器设备问题,分析问题的根源,并提出了相应的改进措施。
  Although the evaporator is very easy to use, it appears in the process of using the evaporator defrosting electric heating tube burned out, the water pan heating room burned out, so the paper introduces the evaporator equipment problems, analyzes the root causes of the problems, and puts forward the corresponding improvement measures.
  你知道蒸发器除霜存在的问题和改进措施吗?
  Do you know the problems in defrosting of evaporator and the improvement measures?
  蒸发器常常不能除霜
  Evaporators often do not defrost
  电热管蒸发器很容易烧坏,因为电热管蒸发器是一组两个串联的加热管,其中一个是烧坏了,线被中断,无法正常工作,所以蒸发器上的霜身体不能融化。
  Electric heat pipe evaporator is easy to burn out, because the electric heat pipe evaporator is a group of two heating pipes in series, one of which is burned out, the wire is interrupted, can not work properly, so the frost body on the evaporator can not melt.
  水盘结冰了
  The water dish has frozen.
  水菜里面没有设置电加热管,虽然有相同的电热丝和水管,但权力很小,质量差,经常失败,由于低温下温度达到18,蒸发器除霜后,水进入放电将复冰锅太迟了,不能正常运行通过排水管。
  There is no electric heating pipe in water vegetable, although there are the same electric heating wire and water pipe, but the power is very small, the quality is poor, and often fails. Because the temperature reaches 18 at low temperature, after defrosting of evaporator, the water enters the refrigerating pot too late to run through the drainage pipe normally.
  下水管结冰了
  The sewer is frozen.
济南空调维修
  落水管电热丝故障。由于落水管电热丝一直处于工作状态,加之其质量较差,所以落水管电热丝故障率很高。由于原来的落水管较长,其电热丝一旦发生故障,在低温环境下,进入落水管的水还没有跑掉并开始结冰,总是不能正常实现除霜。
  Fault of electric heating wire in downcomer. Because the electric heating wire of the downcomer is always in working state and its quality is poor, the failure rate of the electric heating wire of the downcomer is very high. Because the original downspout pipe is long, once its electric heating wire breaks down, in low temperature environment, the water entering the downspout pipe has not run away and began to freeze, and always can not defrost normally.
  改进措施:
  Improvement measures:
  蒸发器不能除霜的主要原因是电加热质量的积累,采用串联方式。因此,我们应该使用额定电压为220v的加热管,并采用并联方式。
  The main reason why the evaporator can not defrost is the accumulation of electric heating quality, which adopts series mode. Therefore, we should use a heating pipe with rated voltage of 220 V and adopt parallel connection.
  集水盘是定制的,确保蒸发器的除霜水到达集水盘后不会冻结两次。
  The catchment pan is customized to ensure that the defrosting water of the evaporator does not freeze twice when it reaches the catchment pan.
  改进的截水管,是把水管尽可能的短,在接水盘下方加一个接水斗,在接水斗内的水还没有满之前,更换新的接水斗。
  The improved water closure is to shorten the water pipe as short as possible, add a water bucket under the water receiving plate, and replace the new water receiving bucket before the water in the water receiving bucket is full.

上一篇:新风系统是中央空调吗?
下一篇:空调维修的具体原则是什么?